Quick Answer

Start with the target device, port, link distance, fiber type and document needs. Then use the article content below to narrow the model path before sending an RFQ.

Catalyst 2960 series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C2960-24TC-L WS-C2960G-24TC-L WS-C2960-48TC-L | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD | | 12.2(25)FX | WS-C2960-24PC-L | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD | | 12.2(44)SE | WS-C2960-24TC-S WS-C2960-48TC-S | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD | | 12.2(37)EY | WS-C2960-8TC-S | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD | | 12.2(46)SE | WS-C2960-48PST-L | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD | | 12.2(46)SE | WS-C2960-8TC-L WS-C2960G-8TC-L | GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD | | 12.2(35)SE | WS-C2960G-48TC-L | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD | | 12.2(25)SEE | WS-C2960-48PST-S WS-C2960-24PC-S WS-C2960-24LC-S | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD | | 12.2(50)SE | Catalyst 2960 Plus Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C2960+48PST-L WS-C2960+24PC-L WS-C2960+24LC-L WS-C2960+48TC-L WS-C2960+24TC-L | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD GLC-ZX-SMD | | 15.0(2)EZ | WS-C2960+48PST-S WS-C2960+24PC-S WS-C2960+24LC-S WS-C2960+48TC-S WS-C2960+24TC-S | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD | | 15.0(2)EZ | Catalyst 2960 S Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C2960S-24TS-S WS-C2960S-48TS-S | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SM | | 12.2(53)SE1 | GLC-EX-SMD [1] | | 12.2(58)SE | WS-C2960S-48FPS-L WS-C2960S-48LPS-L WS-C2960S-24PS-L WS-C2960S-48TS-L WS-C2960S-24TS-L | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD | | 12.2(53)SE1 | GLC-EX-SMD1 | | IOS 12.2(58)SE | WS-C2960S-48FPD-L WS-C2960S-48LPD-L WS-C2960S-24PD-L WS-C2960S-48TD-L WS-C2960S-24TD-L | GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD | | 12.2(53)SE1 | GLC-EX-SMD1 | | IOS 12.2(58)SE | Catalyst 2960 SF Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | 2960S-F48TS-S 2960S-F24TS-S | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD GLC-EX-SMD1 | | 15.0(2)SE | 2960S-F48FPS-L 2960S-F48LPS-L 2960S-F24PS-L 2960S-F48TS-L 2960S-F24TS-L | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD GLC-EX-SMD1 | | 15.0(2)SE | Catalyst 2960 C Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C2960CG-8TC-L | GLC-SX-MM GLC-SX-MMD GLC-LH-SM GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP | | 12.2(55)EX1 | GLC-EX-SMD1 | | 15.0(2)SE | WS-C2960C-8TC-S | GLC-SX-MM GLC-SX-MMD GLC-LH-SM GLC-LH-SMD | | 12.2(55)EX3 | WS-C2960C-8TC-L WS-C2960C-8PC-L WS-C2960C-12PC-L | GLC-SX-MM GLC-SX-MMD GLC-LH-SM GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP | | 12.2(55)EX3 | GLC-EX-SMD1 | | 15.0(2)SE | Catalyst 2960 X Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C2960X-24TS-LL WS-C2960X-48TS-LL | GLC-LH-SMD GLC-SX-MMD GLC-EX-SMD1 GLC-T GLC-TE GLC-LH-SM GLC-SX-MM GLC-GE-100FX | 15.0(2)EX | 15.0(2)EX | WS-C2960X-24PSQ-L | GLC-BX-D GLC-BX-U GLC-LH-SMD GLC-SX-MMD GLC-EX-SMD1 GLC-ZX-SMD GLC-T GLC-TE GLC-ZX-SM GLC-LH-SM GLC-SX-MM | 15.0(2)EX | 15.0(2)EX | WS-C2960X-24PS-L WS-C2960X-24TS-L WS-C2960X-48TS-L WS-C2960X-48LPS-L WS-C2960X-48FPS-L WS-C2960X-24TD-L WS-C2960X-24PD-L WS-C2960X-48TD-L WS-C2960X-48LPD-L WS-C2960X-48FPD-L | GLC-BX-D GLC-BX-U GLC-LH-SMD GLC-SX-MMD GLC-EX-SMD1 GLC-ZX-SMD GLC-T GLC-TE GLC-ZX-SM GLC-LH-SM GLC-SX-MM CWDM-SFP GLC-GE-100FX | 15.0(2)EX | 15.0(2)EX | Catalyst 2960 XR Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C2960XR-24TS-I WS-C2960XR-48TS-I WS-C2960XR-24PS-I WS-C2960XR-48LPS-I WS-C2960XR-48FPS-I WS-C2960XR-24TD-I WS-C2960XR-48TD-I WS-C2960XR-24PD-I WS-C2960XR-48LPD-I WS-C2960XR-48FPD-I | GLC-BX-D GLC-BX-U GLC-LH-SMD GLC-SX-MMD GLC-EX-SMD1 GLC-ZX-SMD GLC-T GLC-TE GLC-ZX-SM GLC-LH-SM GLC-SX-MM CWDM-SFP GLC-GE-100FX | 15.0(2)EX1 | 15.0(2)EX1 | Catalyst 2960 L Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C2960L-8TS-LL WS-C2960L-8PS-LL WS-C2960L-16TS-LL WS-C2960L-16PS-LL WS-C2960L-24TS-LL WS-C2960L-24PS-LL WS-C2960L-48TS-LL WS-C2960L-48PS-LL WS-C2960L-24TQ-LL WS-C2960L-24PQ-LL WS-C2960L-48TQ-LL WS-C2960L-48PQ-LL | GLC-BX-D GLC-BX-U GLC-LH-SMD GLC-SX-MMD GLC-EX-SMD GLC-ZX-SMD GLC-T GLC-ZX-SM GLC-LH-SM GLC-SX-MM CWDM SFP | 15.2(5)E | 15.2(5)E | GLC-TE | | 15.2(5)E2 | Catalyst 2960 CX Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C2960CX-8TC-L WS-C2960CX-8PC-L | GLC-BX-D GLC-BX-U GLC-GE-100FX GLC-LH-SMD GLC-SX-MMD GLC-EX-SMD GLC-ZX-SMD GLC-ZX-SM GLC-LH-SM GLC-SX-MM CWDM SFP | 15.2(3)E | 15.2(3)E | WS-C2960CX-8TC-L WS-C2960CX-8PC-L | GLC-T (10/100/1000) GLC-TE | 15.2(5)E | 15.2(5)E | Catalyst 2970 series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C2970G-24TS-E | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-ZX-SMD GLC-SX-MMD GLC-LH-SMD | | 12.1(14)EA1 | Catalyst 2975 series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C2975GS-48PS-L | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-ZX-SMD CWDM SFP GLC-SX-MMD GLC-LH-SMD | | 12.2(46)EX | Catalyst 3500 Switches Support Catalyst 3500XL series | Network Device | Transceiver Module | Minimum Software Release Required | DOM Support | Software Release | WS-C3508G-XL-EN WS-C3512-XL-EN WS-C3524-XL-EN WS-C3524-PWR-XL-EN WS-C3548-XL-EN | WS-G5482 | | 12.0(5)XW | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC | | 12.0(5)WC3b | Catalyst 3550 series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C3550-24-SMI WS-C3550-24-EMI WS-C3550-24-DC-SMI | WS-G5482 | | 12.1(6)EA1a | WS-G5483 WS-G5484 WS-G5486 WS-G5487 | | 12.1(8)EA1b | CWDM GBIC | | 12.1(12c)EA1 | DWDM GBIC | | 12.1(20)EA2 | WS-C3550-24-FX-SMI WS-C3550-24PWR-SMI WS-C3550-24PWR-EMI | WS-G5482 WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC | | 12.1(12c)EA1 | DWDM GBIC | | 12.1(20)EA2 | WS-C3550-48-SMI WS-C3550-48-EMI | WS-G5482 WS-G5483 WS-G5484 WS-G5486 WS-G5487 | | 12.1(8)EA1b | CWDM GBIC | | 12.1(12c)EA1 | DWDM GBIC | | 12.1(20)EA2 | WS-C3550-12G WS-C3550-12T | WS-G5482 | | 12.1(6)EA1 | WS-G5483 WS-G5484 WS-G5486 WS-G5487 | | 12.1(8)EA1b | CWDM GBIC | | 12.1(12c)EA1 | DWDM GBIC | | 12.1(20)EA2 | Catalyst 3560 series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C3560-24PS WS-C3560-48PS | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.1(19)EA1c | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z | 12.2(46)SE | 12.1(19)EA1c | GLC-BX-D GLC-BX-U | 12.2(46)SE | 12.2(25)SEB | DWDM SFP | 12.2(46)SE | 12.2(40)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | WS-C3560G-24TS WS-C3560G-48TS WS-C3560G-48PS WS-C3560G-24PS | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(20)SE3 | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z | 12.2(46)SE | 12.2(20)SE3 | GLC-BX-D GLC-BX-U | 12.2(46)SE | 12.2(25)SEB | DWDM SFP | 12.2(46)SE | 12.2(40)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | WS-C3560-48TS WS-C3560-24TS | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(20)SE3 | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z | 12.2(46)SE | 12.2(20)SE3 | GLC-BX-D GLC-BX-U | 12.2(46)SE | 12.2(25)SEB | DWDM SFP | 12.2(46)SE | 12.2(40)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | WS-C3560-8PC | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD | | 12.2(35)SE | GLC-ZX-SM GLC-ZX-SMD CWDM SFP GLC-BX-D GLC-BX-U | 12.2(46)SE | 12.2(35)SE | WS-C3560-12PC-S | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD | | 12.2(46)SE | GLC-ZX-SM GLC-ZX-SMD CWDM SFP GLC-BX-D GLC-BX-U | 12.2(46)SE | 12.2(46)SE | WS-C3560V2-24PS WS-C3560V2-24TS WS-C3560V2-48PS WS-C3560V2-48TS | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(50)SE | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD SFP-GE-S SFP-GE-L CWDM SFP GLC-BX-D GLC-BX-U DWDM SFP | 12.2(50)SE | 12.2(50)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | Catalyst 3560 E Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C3560E-24TD WS-C3560E-24PD WS-C3560E-48TD WS-C3560E-48PD WS-C3560E-48PDF With CVR-X2-SFP (for X2 ports) | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(35)SE2 | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z | 12.2(46)SE | 12.2(35)SE2 | DWDM SFP | 12.2(46)SE | 12.2(40)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | WS-C3560E-12D With CVR-X2-SFP (for X2 ports) | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(40)EX | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z | 12.2(46)SE | 12.2(40)EX | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | WS-C3560E-12SD | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(44)SE | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z | 12.2(46)SE | 12.2(44)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | WS-C3560E-12SD With CVR-X2-SFP (for X2 ports) | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(44)SE | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z | 12.2(46)SE | 12.2(44)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | Catalyst 3560 X Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C3560X-24T WS-C3560X-48T WS-C3560X-24P WS-C3560X-48P WS-C3560X-48PF With C3KX-NM-1G and C3KX-NM-10G (slots 1 and 3) network modules | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(53)SE | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U SFP-GE-S SFP-GE-L SFP-GE-Z CWDM SFP DWDM SFP DWDM SFP (add.) | 12.2(53)SE | 12.2(53)SE | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | WS-C3560X-24T WS-C3560X-48T WS-C3560X-24P WS-C3560X-48P WS-C3560X-48PF With C3KX-NM-10G (slots 2 and 4) and C3KX-SM-10G network modules | GLC-SX-MM GLC-LH-SM | | 12.2(53)SE | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U SFP-GE-S SFP-GE-L SFP-GE-Z CWDM SFP DWDM SFP DWDM SFP (add.) | 12.2(53)SE | 12.2(53)SE | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | Catalyst 3560 CX Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C3560CX-8PC-S WS-C3560CX-8TC-S WS-C3560CX-12TC-S WS-C3560CX-12PC-S WS-C3560CX-12PD-S WS-C3560CX-8XPD-S | GLC-BX-D GLC-BX-U GLC-GE-100FX GLC-LH-SMD GLC-SX-MMD GLC-EX-SMD GLC-ZX-SMD GLC-ZX-SM GLC-LH-SM GLC-SX-MM DWDM SFP CWDM SFP | 15.2(3)E | 15.2(3)E | WS-C3560CX-8PC-S WS-C3560CX-8TC-S WS-C3560CX-12TC-S WS-C3560CX-12PC-S WS-C3560CX-12PD-S WS-C3560CX-8XPD-S | GLC-T(10/100/1000 GLC-TE | 15.2(5)E | 15.2(5)E | Catalyst 3560 C Series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C3560CG-8TC-S WS-C3560CG-8PC-S | GLC-SX-MM GLC-SX-MMD GLC-LH-SM GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP | | 12.2(55)EX | GLC-EX-SMD1 | | 15.0(2)SE | WS-C3560C-8PC-S WS-C3560C-12PC-S | GLC-SX-MM GLC-SX-MMD GLC-LH-SM GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP | | 12.2(55)EX3 | GLC-EX-SMD1 | | 15.0(2)SE | Catalyst 3600 Series Switches Support Catalyst 3600 Series | Network Device | Transceiver Module | Minimum Software Release Required | DOM Support | Software Release | WS-C3650-24TS WS-C3650-48TS WS-C3650-24PS WS-C3650-48PS WS-C3650-48FS WS-C3650-24TD WS-C3650-48TD WS-C3650-24PD WS-C3650-48PD WS-C3650-48FD WS-C3650-48FQ WS-C3650-48PQ WS-C3650-48TQ | GLC-T (10/100/1000) GLC-LH-SM GLC-LH-SMD GLC-SX-MM GLC-SX-MMD GLC-EX-SMD1 GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-T SFP-GE-Z DWDM SFP | | XE 3.3.0SE | GLC-BX40-D-I GLC-BX40-DA-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I | | XE 3.7.1E | GLC-TE | | XE 3.6.7E, XE 3.7.5E | WS-C3650-24PD WS-C3650-24PS WS-C3650-24TD WS-C3650-24TS WS-C3650-48PD WS-C3650-48PQ WS-C3650-48PS WS-C3650-48TD WS-C3650-48TQ WS-C3650-48TS | GLC-LH-SM GLC-SX-MM GLC-T (10/100/1000) GLC-ZX-SMD SFP-GE-T | | 16.1.1 | WS-C3650-24PD WS-C3650-24PS WS-C3650-24TD WS-C3650-24TS WS-C3650-48PD WS-C3650-48PQ WS-C3650-48PS WS-C3650-48TD WS-C3650-48TQ WS-C3650-48TS | CWDM-SFP-xxxx DWDM-SFP-xxxx GLC-BX40-DA-I GLC-BX40-D-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I GLC-BX-D GLC-BX-U GLC-EX-SMD GLC-LH-SMD GLC-SX-MMD GLC-ZX-SM SFP-GE-L SFP-GE-S SFP-GE-Z | 16.1.1 | 16.1.1 | WS-C3650-24PDM WS-C3650-48FQM WS-C3650-8X24UQ WS-C3650-12X48UQ WS-C3650-12X48UR | GLC-LH-SMD GLC-SX-MMD GLC-EX-SMD1 GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z DWDM SFP GLC-BX40-D-I GLC-BX40-DA-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I | 16.2.1 | 16.2.1 | GLC-T (10/100/1000) GLC-SX-MM GLC-LH-SM GLC-ZX-SMD SFP-GE-T | | WS-C3650-12X48UQ WS-C3650-12X48UR WS-C3650-24PD WS-C3650-24PDM WS-C3650-24PS WS-C3650-24TD WS-C3650-24TS WS-C3650-48FQM WS-C3650-48PD WS-C3650-48PQ WS-C3650-48PS WS-C3650-48TD WS-C3650-48TQ WS-C3650-48TS WS-C3650-8X24PD WS-C3650-8X24UQ | GLC-TE (10/100/1000) | | 16.3.5 | Catalyst 3700 Series Switches Support Catalyst 3750 series | Network Device | Transceiver Module | Minimum Software Release Required | DOM Support | Software Release | WS-C3750G-12S WS-C3750G-24TS WS-C3750G-48TS WS-C3750G-24PS WS-C3750G-48PS | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.1.(14)EA1 | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z | 12.2(46)SE | 12.1(14)EA1 | GLC-BX-D GLC-BX-U | 12.2(46)SE | 12.2(25)SEB | DWDM SFP | 12.2(46)SE | 12.2(40)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | WS-C3750-24TS WS-C3750-48TS | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.1(14)EA1 | GLC-SX-MMD GLC-LH-SMD | 12.2(46)SE | 12.1(14)EA1 | GLC-ZX-SM GLC-ZX-SMD CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z | 12.2(46)SE | 12.1(19)EA1c | GLC-BX-D GLC-BX-U | 12.2(46)SE | 12.2(25)SEB | DWDM SFP | 12.2(46)SE | 12.2(40)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | WS-C3750-24PS WS-C3750-48PS | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.1(19)EA1c | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z | 12.2(46)SE | 12.1(19)EA1c | GLC-BX-D GLC-BX-U | 12.2(46)SE | 12.2(25)SEB | DWDM SFP | 12.2(46)SE | 12.2(40)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | WS-C3750-24FS-S | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(25)SEB | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD SFP-GE-S SFP-GE-L SFP-GE-Z CWDM SFP GLC-BX-D GLC-BX-U | 12.2(46)SE | 12.2(25)SEB | DWDM SFP | 12.2(46)SE | 12.2(40)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | WS-C3750-24WFS | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-SX-MM GLC-LH-SM | | 12.2(25)FZ | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD SFP-GE-S SFP-GE-L SFP-GE-Z CWDM SFP GLC-BX-D GLC-BX-U | 12.2(46)SE | 12.2(25)FZ | DWDM SFP | 12.2(46)SE | 12.2(40)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | WS-C3750V2-24PS WS-C3750V2-24TS WS-C3750V2-48PS WS-C3750V2-48TS WS-C3750V2-24FS (uplink ports) | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(50)SE | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD SFP-GE-S SFP-GE-L SFP-GE-Z CWDM SFP GLC-BX-D GLC-BX-U DWDM SFP | 12.2(50)SE | 12.2(50)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | Catalyst 3750-E series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C3750E-24TD WS-C3750E-24PD WS-C3750E-48TD WS-C3750E-48PD WS-C3750E-48PDF With CVR-X2-SFP (for X2 ports) | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(35)SE2 | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z | 12.2(46)SE | 12.2(35)SE2 | DWDM SFP | 12.2(44)SE | 12.2(40)SE | DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | Catalyst 3750-X series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | WS-C3750X-24T WS-C3750X-48T WS-C3750X-24P WS-C3750X-48P WS-C3750X-48PF With C3KX-NM-1G and C3KX-NM-10G (slots 1 and 3) network modules | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(53)SE | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z DWDM SFP DWDM SFP (add.) | 12.2(53)SE | 12.2(53)SE | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | WS-C3750X-24T WS-C3750X-48T WS-C3750X-24P WS-C3750X-48P WS-C3750X-48PF With C3KX-NM-10G (slots 2 and 4) and C3KX-SM-10G network modules | GLC-SX-MM GLC-LH-SM | | 12.2(53)SE | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z DWDM SFP DWDM SFP (add.) | 12.2(53)SE | 12.2(53)SE | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | WS-C3750X-12S WS-C3750X-24S Client ports and uplink ports with C3KX-NM-1G and C3KX-NM-10G (slots 1 and 3) network modules | GLC-T (10/100/1000) GLC-TE GLC-SX-MM GLC-LH-SM | | 12.2(55)SE5 | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z DWDM SFP DWDM SFP (add.) | 12.2(55)SE5 | 12.2(55)SE5 | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | WS-C3750X-12S WS-C3750X-24S Uplink ports with C3KX-NM-10G (slots 2 and 4) and C3KX-SM-10G network modules | GLC-SX-MM GLC-LH-SM | | 12.2(55)SE5 | GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-Z DWDM SFP DWDM SFP (add.) | 12.2(55)SE5 | 12.2(55)SE5 | GLC-EX-SMD1 | 12.2(58)SE | 12.2(58)SE | Catalyst 3800 Series Switches Support Catalyst 3850 series | Network Device | Transceiver Module | Minimum Software Release Required | DOM Support | Software Release | C3850-NM-4-1G Uplink Module | GLC-T (10/100/1000) GLC-LH-SM GLC-LH-SMD GLC-SX-MM GLC-SX-MMD GLC-EX-SMD1 GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-T SFP-GE-Z DWDM SFP DWDM SFP (add.) | | XE 3.2.0SE | WS-C3850-12S WS-C3850-24S | XE 3.3.3SE | XE 3.3.3SE | GLC-BX40-D-I GLC-BX40-DA-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I | XE 3.7.1E | XE 3.7.1E | GLC-TE | | XE 3.6.7E, XE 3.7.5E | WS-C3850-12XS WS-C3850-16XS WS-C3850-24XS WS-C3850-32XS (with C3850-NM-8-10G NM) | GLC-T (10/100/1000) GLC-LH-SM GLC-LH-SMD GLC-SX-MM GLC-SX-MMD GLC-EX-SMD1 GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-T SFP-GE-Z DWDM SFP DWDM SFP (add.) GLC-BX40-D-I GLC-BX40-DA-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I | XE 3.7.1E | XE 3.7.1E | GLC-TE | | XE 3.7.5E | WS-C3850-48XS-S WS-C3850-48XS-E WS-C3850-48XS-F-S WS-C3850-48XS-F-E WS-C3850-48XS | GLC-T (10/100/1000) GLC-LH-SM GLC-LH-SMD GLC-SX-MM GLC-SX-MMD GLC-EX-SMD1 GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-T SFP-GE-Z DWDM SFP DWDM SFP (add.) GLC-BX40-D-I GLC-BX40-DA-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I | XE 3.7.2E | XE 3.7.2E | GLC-TE | | XE 3.7.5E | C3850-NM-1G C3850-NM-2-10G C3850-NM-4-10G C3850-NM-8-10G WS-C3850-12S WS-C3850-12XS WS-C3850-24S WS-C3850-24XS | GLC-LH-SM GLC-SX-MM GLC-T (10/100/1000) GLC-ZX-SMD SFP-GE-T | | 16.1.1 | CWDM-SFP-xxxx DWDM-SFP-xxxx GLC-BX40-DA-I GLC-BX40-D-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I GLC-BX-D GLC-BX-U GLC-EX-SMD GLC-LH-SMD GLC-SX-MMD GLC-ZX-SM SFP-GE-L SFP-GE-S SFP-GE-Z | 16.1.1 | WS-C3850-48XS | GLC-LH-SM GLC-SX-MM GLC-T (10/100/1000) GLC-ZX-SMD SFP-GE-T | | 16.2.1 | CWDM-SFP-xxxx DWDM-SFP-xxxx GLC-BX40-DA-I GLC-BX40-D-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I GLC-BX-D GLC-BX-U GLC-EX-SMD GLC-LH-SMD GLC-SX-MMD GLC-ZX-SM SFP-GE-L SFP-GE-S SFP-GE-Z | 16.2.1 | C3850-NM-1G C3850-NM-2-10G C3850-NM-4-10G C3850-NM-8-10G WS-C3850-12S WS-C3850-12XS WS-C3850-24S WS-C3850-24XS WS-C3850-48XS | GLC-TE (10/100/1000) | | 16.3.5 | Catalyst 9300 Series Switches Support Catalyst 9300 series | Network Device | Transceiver Module | Minimum Software Release Required | DOM Support | Software Release | C9300-24T C9300-24P C9300-24U C9300-24UX C9300-48T C9300-48P C9300-48U (With C9300-NM-8X, or C9300-NM-4G, or C3850-NM-4-1G, or C3850-NM-8-10G for 1G uplink modules) | GLC-LH-SM GLC-LH-SMD GLC-SX-MM GLC-SX-MMD GLC-EX-SMD1 GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-T SFP-GE-Z DWDM SFP DWDM SFP (add.) GLC-BX40-D-I GLC-BX40-DA-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I | | XE 16.5.1a | GLC-T GLC-TE | | XE 16.5.1a | C9300-48UXM (With C9300-NM-8X, or C9300-NM-4G, or C3850-NM-4-1G, or C3850-NM-8-10G for 1G uplink modules) | GLC-LH-SM GLC-LH-SMD GLC-SX-MM GLC-SX-MMD GLC-EX-SMD GLC-ZX-SM GLC-ZX-SMD GLC-BX-D GLC-BX-U CWDM SFP SFP-GE-S SFP-GE-L SFP-GE-T SFP-GE-Z DWDM SFP DWDM SFP (add.) GLC-BX40-D-I GLC-BX40-DA-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I GLC-T GLC-TE | | XE 16.6.2 | C9300-NM-4G C9300-NM-8X | GLC-LH-SM GLC-SX-MM GLC-T (10/100/1000) GLC-TE (10/100/1000) GLC-ZX-SMD SFP-GE-T | | 16.5.1 | CWDM-SFP-xxxx DWDM-SFP-xxxx GLC-BX40-DA-I GLC-BX40-D-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I GLC-BX-D GLC-BX-U GLC-EX-SMD GLC-LH-SMD GLC-SX-MMD GLC-ZX-SM SFP-GE-L SFP-GE-S SFP-GE-Z | 16.5.1 | Catalyst 9400 Series Switches Support Catalyst 9400 series | Network Device | Transceiver Module | Minimum Software Release Required | DOM Support | Software Release | C9400-SUP-1 | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-LH-SM GLC-SX-MM GLC-ZX-SMD | | XE 16.6.1 | GLC-ZX-SM GLC-BX-D GLC-BX-U GLC-SX-MMD GLC-LH-SMD CWDM-SFP-xxxx DWDM-SFP-xxxx | XE 16.6.1 | C9400-Sup-1XL C9400-LC-24XS | GLC-ZX-SM GLC-BX-D GLC-BX-U GLC-SX-MMD GLC-LH-SMD CWDM-SFP-xxxx DWDM-SFP-xxxx | XE 16.6.2 | XE 16.6.2 | GLC-T (1000BASE-T) GLC-TE (1000BASE-T) GLC-LH-SM GLC-SX-MM GLC-ZX-SMD | | Catalyst 9500 Series Switches Support Catalyst 9500 series | Network Device | Transceiver Module | Minimum Software Release Required | DOM Support | Software Release | C9500-NM-8X C9500-40X | GLC-LH-SM GLC-SX-MM GLC-T (10/100/1000) GLC-TE (10/100/1000) GLC-ZX-SMD SFP-GE-T | | XE 16.6.1 | CWDM-SFP-xxxx DWDM-SFP-xxxx GLC-BX40-DA-I GLC-BX40-D-I GLC-BX40-U-I GLC-BX80-D-I GLC-BX80-U-I GLC-BX-D GLC-BX-U GLC-EX-SMD GLC-LH-SMD GLC-SX-MMD GLC-ZX-SM SFP-GE-L SFP-GE-S SFP-GE-Z | XE 16.6.1 | Industrial Ethernet and Smart Grid Support Cisco IE1000 series | Network Device | Transceiver Module | Minimum Software Release Required | DOM Support | Software Release | IE-1000-4P2S-LM IE-1000-8P2S-LM | GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD GLC-SX-MM* GLC-SX-MMD* GLC-LH-SM* GLC-LH-SMD* GLC-EX-SMD* GLC-BX-D* GLC-BX-U* GLC-BX40-U-I GLC-BX40-DA-I GLC-BX80-U-I GLC-BX80-D-I GLC-T* GLC-TE* | | 1.3 | *When using non-rugged/not industrial -rated transceivers, the hardened platform temperature range is de-rated. Cisco IE2000 series | Network Device | Transceiver Module | Minimum Software Release Required | DOM Support | Software Release | IE-2000-4TS-G-L IE-2000-4TS-G-B IE-2000-4S-TS-G-L IE-2000-4S-TS-G-B IE-2000-8TC-G-L IE-2000-8TC-G-B IE-2000-8TC-G-E IE-2000-8TC-G-N IE-2000-16TC-G-L IE-2000-16TC-G-E IE-2000-16TC-G-X IE-2000-16TC-G-N IE-2000-16PTC-G-L IE-2000-16PTC-G-E IE-2000-16PTC-G-NX | GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD SFP-GE-S* SFP-GE-L* SFP-GE-Z* GLC-ZX-SM* GLC-SX-MMD* GLC-LH-SMD* GLC-EX-SMD* GLC-ZX-SMD* GLC-BX-D* GLC-BX-U* CWDM-SFP-xxxx* DWDM-SFP-xxxx* | 15.0(1)EY | 15.0(1)EY | GLC-SX-MM* GLC-LH-SM* | | 15.0(1)EY | GLC-T* GLC-TE* | | 15.2(1)EY | GLC-BX40-U-I GLC-BX40-D-I GLC-BX40-DA-I GLC-BX80-U-I GLC-BX80-D-I | 15.2(3)EA | 15.2(3)EA | *When using non-rugged/not industrial -rated transceivers, the hardened platform temperature range is de-rated. Cisco IE2000U series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | IE 2000U-4TS-G IE 2000U-8TC-G IE 2000U-16TC-G IE 2000U-16TC-G-X IE 2000U-16TC-GP | GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD SFP-GE-S* SFP-GE-L* SFP-GE-Z* GLC-ZX-SM* GLC-SX-MMD* GLC-LH-SMD* GLC-EX-SMD* GLC-ZX-SMD* GLC-BX-D* GLC-BX-U* CWDM-SFP-xxxx* DWDM-SFP-xxxx* | 15.0(2)EK1 | 15.0(2)EH | GLC-SX-MM* GLC-LH-SM* | | 15.0(2)EH | GLC-T* GLC-TE* | | 15.2(4)EA | GLC-BX40-U-I GLC-BX40-D-I GLC-BX40-DA-I GLC-BX80-U-I GLC-BX80-D-I | 15.2(3)EA | 15.2(3)EA | IE-2000U-4S-G | GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD SFP-GE-S* SFP-GE-L* SFP-GE-Z* GLC-ZX-SM* GLC-SX-MMD* GLC-LH-SMD* GLC-EX-SMD* GLC-ZX-SMD* GLC-BX-D* GLC-BX-U* CWDM-SFP-xxxx* DWDM-SFP-xxxx* | 15.0(2)EK1 | 15.0(2)EK1 | GLC-SX-MM* GLC-LH-SM* | | 15.0(2)EK1 | GLC-T* GLC-TE* | | 15.2(4)EA | GLC-BX40-U-I GLC-BX40-D-I GLC-BX40-DA-I GLC-BX80-U-I GLC-BX80-D-I | 15.2(3)EA | 15.2(3)EA | *When using non-rugged/not industrial -rated transceivers, the hardened platform temperature range is de-rated. Cisco IE3000 series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | IE-3000-4TC IE-3000-8TC | GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD SFP-GE-S* SFP-GE-L* SFP-GE-Z* GLC-ZX-SM* GLC-SX-MMD* GLC-LH-SMD* GLC-ZX-SMD* GLC-BX-D* GLC-BX-U* CWDM-SFP-xxxx* DWDM-SFP-xxxx* | 12.2(44)EX | 12.2(44)EX | GLC-SX-MM* GLC-LH-SM* GLC-T* GLC-TE* | | 12.2(44)EX | GLC-EX-SMD* | 12.2(58)SE1 | 12.2(58)SE1 | GLC-BX40-U-I GLC-BX40-D-I GLC-BX40-DA-I GLC-BX80-U-I GLC-BX80-D-I | 15.2(3)EA | 15.2(3)EA | *When using non-rugged/not industrial -rated transceivers, the hardened platform temperature range is de-rated. Cisco IE3010 series | Network Device | Transceiver Model | Minimum Software Release Required | DOM Support | Software Release | IE-3010-24TC IE-3010-16S-8PC | GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD SFP-GE-S* SFP-GE-L* SFP-GE-Z* GLC-ZX-SM* GLC-SX-MMD* GLC-LH-SMD* GLC-ZX-SMD* GLC-BX-D* GLC-BX-U* CWDM-SFP-xxxx* DWDM-SFP-xxxx* | 12.2(53)EZ | 12.2(53)EZ | GLC-SX-MM* GLC-LH-SM* | | 12.2(53)EZ | GLC-BX40-U-I GLC-BX40-D-I GLC-BX40-DA-I GLC-BX80-U-I GLC-BX80-D-I | 15.2(3)EA | 15.2(3)EA | GLC-EX-SMD* | 15.0(2)SE | 15.0(2)SE | GLC-T* GLC-TE* | | Not Supported (Has Combo Ports) | *When using non-rugged/not industrial -rated transceivers, the hardened platform temperature range is de-rated. The next page [2]

Compatibility Checklist

Before requesting pricing, collect the details that affect coding review and quote quality.

Device information

Device brand, model, firmware or OS version, target port and required module code.

Link information

Required reach, fiber type, connector, wavelength plan and deployment environment.

Purchase context

Quantity, destination country, required delivery target and packaging or labeling needs.

Proof documents

Datasheet, catalog, test report request, certificate path or inspection record requirement.

FAQ

What information is needed for compatibility review?

Submit brand, device model, firmware or OS, target port, required module code and quantity.

Can I request a datasheet before ordering?

Yes. Use the datasheet center or RFQ form to request the current file version for the target model.

What should I include in an RFQ?

Product variant, quantity, country, target device, reach, connector, required documents and deployment notes.

Where can I review testing or compliance paths?

Use the Testing & Quality and Certifications & Compliance pages, then request project documents through the RFQ.