Quick Answer
Start with the target device, port, link distance, fiber type and document needs. Then use the article content below to narrow the model path before sending an RFQ.
The amount of data that can be transferred over even simple unshielded twisted-pair cables has increased dramatically over the last few years. Many experts in the late 1980s believed that UTP cables would not support data rates in excess of 10Mbps. Today, cables of 100 meters typically support data rates of 10Gbps. It is even possible that UTP cables could achieve greater data rates in the future. When looking at a typical cabling catalog, there are more than 2,000 different cable types listed. The modern cabling world nowadays uses a huge range of engineering terms and communication buzzwords. Cable design complexity has increased dramatically with the need for faster data rates. With an increase in data rates, what happens inside the cables becomes increasingly complex, while the probability that data signals will be corrupted also increases. The cable's electrical properties change when the data rates increases, signal travel distance decreases and signal distortion becomes more prevalent. Manufacturers of cables supporting frequencies bigger than 100MHz and 1000Base-T (Gigabit Ethernet) are faced with electrical problems that are not encountered at lower data rates and frequencies. These problems include arrival delays of the signal on different pairs of wires and different varieties of crosstalk. High-Speed Data Transfer Obstacles Electricity consists of electrons flowing inside a cable and colliding with each other. For a signal to be transmitted correctly, enough electrons must flow through the cable from the sender to the receiver. When the frequency, and as a result the potential data rate, increases in a cable, a number of factors obstruct the signal's travel. These factors are important to both the person responsible for testing and certifying the cable and the person responsible for authorizing cable purchases. Category 5e, 6, 6A, 7, and 7A cabling specifications list a number of these factors and the maximum (or minimum) acceptable values that cables can have to still be compliant. Both 1000Base-T Ethernet and 10GBase-T uses complex modulation technology, resulting in the TIA specifying additional cabling performance characteristics which were not included in the original specifications. These include pair-to-pair crosstalk and power-sum measurements, return loss, delay skew, ACR-N and ACR-F. Some of the new performance characteristics relate to crosstalk, for example AN'EXT (near-end alien crosstalk) and AXT: AACRF (attenuation to alien crosstalk ratio, far-end), both used to express interaction between cables in a bundle. Although crosstalk should be considered in all technologies, fast technologies such as 1000Base-T and 10GBase-T are more sensitive as they use four pairs in parallel for transmissions. These new requirements are included in the current versions of the ANSI/TIA-568-C and ISO/IEC 11801 Ed. 2.2 standards. Many transmission requirements are based on intricate mathematical formulas. For ease of use, values are calculated and listed in the specification for selected frequencies. The actual requirement is however that the parameter must pass the test across the full bandwidth applicable to the cable category. This means that performance must be in accordance with the formula and consistent at any given frequency, from the lowest to the highest frequency specified. The major 17 test parameters for communication cables are listed below: Attenuation (signal-loss) Mutual capacitance (1) Conductor resistance (2) Insertion loss (3) Return loss (4) Impedance (5) Noise Capacitance unbalance (6) Resistance unbalance (7) Far-end crosstalk (FEXT) (8) Near-end crosstalk (NEXT) (9) Power-sum FEXT (10) Power-sum NEXT (11) Power-sum ACR-F, ACR-N (12) Power-sum AACRF, ANEXT (13) Alien crosstalk (AACRF, ANEXT) (14) Attenuation-to-crosstalk ratio (ACR-F, ACR-N) (15) Other Delay skew (16) Propagation delay (17)
Compatibility Checklist
Before requesting pricing, collect the details that affect coding review and quote quality.
Device information
Device brand, model, firmware or OS version, target port and required module code.
Link information
Required reach, fiber type, connector, wavelength plan and deployment environment.
Purchase context
Quantity, destination country, required delivery target and packaging or labeling needs.
Proof documents
Datasheet, catalog, test report request, certificate path or inspection record requirement.
FAQ
What information is needed for compatibility review?
Submit brand, device model, firmware or OS, target port, required module code and quantity.
Can I request a datasheet before ordering?
Yes. Use the datasheet center or RFQ form to request the current file version for the target model.
What should I include in an RFQ?
Product variant, quantity, country, target device, reach, connector, required documents and deployment notes.
Where can I review testing or compliance paths?
Use the Testing & Quality and Certifications & Compliance pages, then request project documents through the RFQ.